All Categories > Sensors > Thermocouples > General Applications Tube and Wire 
 

General Applications Tube and Wire

Click on a Product to view details.

Request Information
Schematic

Adjustable Spring Style Thermocouple

Adjustable spring style thermocouple fits a large range of hole depths. Bends to any angle, eliminating the requirement to stock numerous styles.

View General Information

See Related Spec Sheets.

Schematic

Adjustable Armor Style Thermocouple

Adjustable armor thermocouple fits a large range of hole depths. Bends to any angle, eliminating the requirement to stock numerous styles. Stainless steel hose offers assitional lead protection in demanding appications.

View General Information

See Related Spec Sheets.

Schematic

Rigid Sheath

Rigid sheath provides protection and accurate placement through bulkheads or platens. Use with a compression fitting for water tight immersion application.
Bent rigid tube offers protection and accurate lead placement around machinery.

View General Information

See Related Spec Sheets.

Schematic

Rigid Sheath with Threaded Fitting

Rigid sheath with threaded fitting provides accurate placement in process applications.

View General Information

See Related Spec Sheets.

Schematic

PFA Encapsulated Style

The rigid sheath is covered with a 0.010 inch (25 mm) wall of PFA for corrosion resistance in acid environments. An epoxy seal improves moisture resistance of sensor and provides a barrier for migrating fumes in corrosive applications.

View General Information

See Related Spec Sheets.

Schematic

Flange Style

The flanged thermocouple allows rapid assembly and low profile when going through bulkheads.

Note: Metric sizes available for made-to-order units, consult factory. Minimum order quantity may apply.

View General Information

See Related Spec Sheets.

Schematic

Rigid Sheath Fixed Bayonet Style

Bayonet fittings allow rapid attachment. Spring pressure on the junction tip assures fast response time.
This style of bayonet fitting is quick connecting and allows leads to exit with a protective sheath.

View General Information

See Related Spec Sheets.

Schematic

Large Diameter Rigid Sheath Style

Rigid sheath provides protection and accurate placement through bulkheads or platens. Use with a compression fitting for water tight immersion application.
Bent rigid tube offers protection and accurate lead placement around machinery.

View General Information

See Related Spec Sheets.

Schematic

Flexible Extensions

Flexible extensions allow the disconnecting of thermocouples from a system without disturbing the remaining wiring.

View General Information

See Related Spec Sheets.

Schematic

Insulated Wire Thermocouple Style 61 and Style 62

Constructed with SERV-RITE® insulated thermocouple wire Styles 61 and 62 are economical and versatile thermocouples with the option of an exposed or protected measuring junction.
Style 61 has an exposed junction and is suitable for most general purpose applications, such as measuring air, gas and surface temperatures.
Style 62 has an encapsulated measuring junction that is ideal for corrosive fluids and gases such as sulfuric acid, hydrofluoric acid, strong mineral acids and oils.

View General Information

See Related Spec Sheets.

Schematic

Ring Terminal Style

The nickel terminal can be placed beneath existing screws or bolts to permit surface temperature measurement.

View General Information

See Related Spec Sheets.

Schematic

Nozzle Style

The nozzle thermocouple has a short installation depth and a low profile thus allowing control of thin sections of platens.

View General Information

See Related Spec Sheets.

Schematic

Pipe Clamp Style

The stainless steel clamp allows temperature measurement without drilling or tapping. Ideal for measuring pipe temperatures.

View General Information

See Related Spec Sheets.

Schematic

Grommet Style

Extremely low profile of the stainless steel grommet provides fast response time.

View General Information

See Related Spec Sheets.

Schematic

Brass Shim Style

The shim stock thermocouple has low profile and can be placed between components for measurement of surface temperature.
Available in other shim dimensions.

View General Information

See Related Spec Sheets.

Schematic

Stainless Steel Shim Style

The shim stock thermocouple has low profile and can be placed between components for measurement of surface temperature.
Available in other shim dimensions.

View General Information

See Related Spec Sheets.

kapton

Kapton® Bracket Style

 (16)

View General Information

See Related Spec Sheets.

Schematic

Melt Bolt Thermocouple

Watlow plastic melt bolt thermocouples are designed so that the sensitive closed end portion of the tip can be inserted directly into the plastic stream of an extruder or injection molding machine. The measuring junction is thermally isolated from the metal bolt mass, assuring accurate reading of the melt temperature up to 260°C (500°F) continuous. Bolt is 300 series stainless steel.

View General Information