All Categories > Power Switching Devices > DIN-A-MITE B Power Controller 
    Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

DIN-A-MITE B Power Controller


Configure ProductRequest Information
The DIN-A-MITE B power controller provides a low-cost, highly compact and versatile solid state option for controlling electric heat. The DIN-A-MITE B capabilities include single-phase and three-phase zero-cross switching up to 40 and 22 amperes, respectively at 600VAC (see rating curve). This controller's design includes proper heat sinking and terminations simplifying integration into applications. DIN-rail and back panel mounting is standard on this family of controllers. The DIN-A-MITE controller is also mercury free.

Variable time base, 4-20mA process control or VAC/VDC input contactor versions are available. A shorted silicon controlled rectifier (SCR) alarm option is also available. All options are model number dependent and factory configurable. This power controller also includes 200KA short circuit current rating (SCCR) tested up to 480VAC to prevent arch flash with required fusing.



Specifications · Features and Benefits

Specifications

Dimensions
  • Height: 3.7 in. (95 mm) high x 3.1 in. (80 mm) wide x 4.9 in. (124 mm) deep
  • Weight: 1.5 lb (0.68kg)
Operator Interface
  • Command signal input and indication light
  • Alarm output and indication light
Amperage Rating
  • See the output rating curve
  • Max. surge current for 16.6ms, 380A peak
  • Max. I2t for fusing is 4,000A2s
  • Latching current: 200mA min.
  • Holding current: 100mA min.
  • Off-state leakage 1mA at 77ºF (25ºC) max.
  • Power dissipation = 1.2 watts per amperes per leg switched
  • 200KA SCCR, Type 1 and 2 approved with the recommended fusing; see user manual
Line Voltage
  • 20 to 660VAC model number dependent; see ordering information
Control Mode, Zero-Cross
  • Input control signal Type C: VDC input contactor
  • Input control signal Type K: VAC input contactor
  • To increase service life on contactor input models the cycle time should be less than three seconds
  • Input Control Signal Type F: 4 to 20mA DC proportional variable time base control
Input Command Signal
  • AC contactor
    24VAC ±10%, 120VAC +10/-25%, 240VAC +10/-25% @ 25mA max. per controlled leg
  • DC Contactor
    4.5 to 32VDC: max. current @ 4.5VDC is 6mA per leg. Add 2mA per LED used to the total current
  • Loop powered linear current
    4 to 20mA DC: loop-powered, input Type F0 option only (requires current source with 6.2VDC available, no more than three DIN-A-MITE inputs connected in series); 3 cycles on, 3 cycles off at 50% power
Alarm
Shorted SCR Alarm Option
  • Alarm state when the input command signal off and a 10A or more load current is detected by the current transformer (two turns required for 5A and three turns for 2.5A)
Alarm Output
  • Energizes on alarm, non-latching
  • Triac 24 to 240VAC, external supply with a current rating of 300mA @ 77ºF (25ºC), 200mA @ 122ºF (50ºC), 100mA @ 176ºF (80ºC) and a holding current of 200μA with a latching current of 5mA typical
Agency Approvals
  • CE with proper filter:
    204/108/EC electromagnetic compatibility directive
      EN 61326-1: industrial immunity class A emissions
    2006/95/EC low voltage directive
      EN 50178 safety requirements
    Installation category III, pollution degree 2
  • cULus® UL® 508 listed and C-UL® File E73741
Input Terminals
  • Compression: will accept 24 to 16 AWG (0.2. to 1.5 mm2) wire
Line and Load Terminals
  • Compression: will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire
Operating Environment
  • See the output rating curve
  • 0 to 90% RH (relative humidity), non-condensing
  • Storage temperature: -40 to 185ºF (-40 to +85ºC)
  • Insulation tested to 3,000 meters
DIN-rail Mount
  • DIN EN 50022, 1.3 in. (35 mm) by 0.3 in. (7.5 mm)
Back Panel Mount
  • Four mounting holes M3 to M4 (No. 6 to No. 8) fastener
Specifications are subject to change without notice.


Features and Benefits

200KA SCCR with proper fusing

  • Minimizes damage in the event of a short circuit

    DIN-rail or standard panel mount

  • Provides versatility, quickness and low-cost installation

    Compact size

  • Reduces panel space and cost

    Touch-safe terminals

  • Increases safety for installer and users

    Single and three-phase power

  • Permits use in a variety of applications

    Mercury free

  • Environmentally safe

    Faster switching with solid state

  • Saves energy and extends heater life

    UL® 508 listed, C-UL® and CE with filter

  • Meets applications requiring agency approval

    Back-to-back SCR design

  • Ensures a rugged design

    Shorted output alarm (optional)

  • Notifies the user in case of a shorted SCR



  •  MORE IMAGES 

    · Output Rating Curve

    · Current Rating Table


     Fuses 


    DFJ Fuses

    DFJ Fuses


    DFJ Single Fuse Holder

    DFJ Single Fuse Holders