The EZ-ZONE® RM controller simplifies thermal system management. The EZ-ZONE RM controller family is comprised of six module types: an integrated on-off or PID control, monitoring and over/under temperature limit module, a high-density on-off or PID control module, a high-density limit only module, an input/output (I/O) expansion module, a high-density monitor/scanner module and a data logging and field communications access module. A system is configured by connecting any combination of module types to address specific application needs. The EZ-ZONE RM is extremely flexible and scalable allowing mixing and matching of I/O to configure 1 to 152 control loops and up to 256 monitor points.

Optional integrated controller functions can be combined or ordered in different quantities:
  • PID control loops
  • Over/under temperature limit control loops
  • 10 and 15 ampere power output/heater driver options
  • On-board data logging
  • Current measurement input
  • Sequencer start up and control function
  • Programmable timer and counter functions
  • Programmable math and logic options
  • Multiple communication protocol options
  • Mobile configuration with removable secure digital (SD) flash card
Benefits of using an integrated controller solution:
  • Reduces wiring time and termination complexity compared with connecting multiple discrete products
  • Improves system reliability
  • Reduces termination and installation cost
  • Eliminates compatibility issues often encountered with using various discrete components and brands
  • Reduces troubleshooting time and downtime costs because the system can specifically identify any problems with a sensor, controller, solid state relay (SSR) power output or heater load
  • Complete thermal solution saves engineering time and labor costs while shortening project schedules


EZ-ZONE® RM High-Density Limit Module

larger image

Dimensional Drawing of EZ-ZONE® RM

larger image



Features and Benefits · Additional Key Functions · Common Specifications (Applies to all models) · Programmable Application Blocks · Access Module Specifications (RMA) · Compatible Accessories

Features and Benefits

Multiple inputs; from 1 to 152 PID loops of control or monitor up to 256 analog inputs
  • Mix and match I/O to fit any application; from 1 input with 2 outputs to 152 analog inputs with 152 outputs, or monitor up to as many as 256 analog inputs all in one system
  • Reduces cost because only required loops are purchased
  • Allows a common controller platform across many design applications as both loops and outputs can be ordered in single increments
Advanced PID control algorithm
  • Offers TRU-TUNE® + adaptive control to provide tighter control for demanding applications
  • Enables auto-tune for fast, efficient start-up
Communication capabilities
  • Provides a range of protocol options including universal serial bus (USB) device port, Modbus® RTU, EtherNet/IP™, Mod bus® TCP, DeviceNet™ and PROFIBUS
USB Port
  • Provides data log retrieval
SPLIT-RAIL control
  • Enables modules mounted in separate high-voltage and low-voltage cabinets to function as an integrated system
  • Minimizes the length and cost of wire runs and improves system reliability by locating inputs closer to sensors and outputs closer to loads
AUTO CLONE
  • Reduces time and configuration complexity by automatically building a new module with the same parameter settings as the replaced module
SENSOR GUARD
  • Prevents unplanned process shutdowns and product loss by switching to a backup sensor if the primary sensor fails
1 to 128 loop limit controller
  • Eliminates compatability issues often encountered with using many different discrete components and brands
  • Saves engineering time and labor costs while shortening project schedules
  • Allows a common limit controller platform across many design applications
Communications
  • Allows standard bus communications
  • Ability to utilize EIA 485, Modbus® RTU options



Additional Key Functions

  • Configuration communication port (standard bus)
  • Removable modules and connectors
  • Ring lug and front-screw terminal options
  • Profile ramp soak with 400 total steps
  • Retransmit and remote set point input virtually inside
    controller eliminating costs for input/output hardware
  • User configuration settings can be stored and recalled
  • Thermistor input
  • Elevated operating range of 0 to 149ºF (-18 to 65ºC)
  • UL® listed, CSA, CE, RoHS, W.E.E.E. FM, SEMI F47-0200, Class 1, Div. 2 rating on selected models



Common Specifications (Applies to all models)

Line Voltage/Power
  • 20.4 to 30.8VAC/VDC, 50/60Hz ±5%
  • Any external power supply used should comply with a Class 2 or SELV rating (see specific module specification listing for max. VA power consumption)
  • Data retention upon power failure via non-volatile memory
  • Compliant with Semi F47-0200, Figure R1-1 voltage sag requirements
Environment
  • 0 to 149ºF (-18 to 65ºC) operating temperature
  • -40 to 185ºF (-40 to 85ºC) storage temperature
  • 0 to 90% RH, non-condensing
Functional Operating Range for RMC, RMH, RML and RMS
Type J: -346 to 2192ºF (-210 to 1200ºC)
Type K: -454 to 2500ºF (-270 to 1371ºC)
Type T: -454 to 750ºF (-270 to 400ºC)
Type E: -454 to 1832ºF (-270 to 1000ºC)
Type N: -454 to 2372ºF (-270 to 1300ºC)
Type C: 32 to 4200ºF (0 to 2315ºC)
Type D: 32 to 4200ºF (0 to 2315ºC)
Type F: 32 to 2449ºF (0 to 1343ºC)
Type R: -58 to 3214ºF (-50 to 1767ºC)
Type S: -58 to 3214ºF (-50 to 1767ºC)
Type B: 32 to 3300ºF (0 to 1816ºC)
RTD (DIN): -328 to 1472ºF (-200 to 800ºC)
Process: -1999 to 9999 units

Agency Approvals
  • UL®/EN 61010 Listed, C-UL® C22.2 #61010ANSI/ISA 12.12.01-2007 Class 1, Div. 2-Group A, B, C, D temperature code T4 (optional)
  • UL® 1604 Class 1, Div. 2 (optional)
  • EN 60529 IP20
  • UL® 50, NEMA 4X, EN 60529 IP66; 1/16 DIN remote user interface (RUI)
  • CSA 610110 CE
  • RoHS by design, W.E.E.E.
  • FM Class 3545 on limit control versions
  • CE
Serial Communications
  • All modules ship with standard bus protocol for configuration and communication with all other EZ-ZONE products
Implicit Messaging
Number of data members accessible through implicit messaging

User Interface
  • Seven-segment LED, address/protocol indicator programmed via push button switch
  • Communication activity, 2 LEDs
  • Error condition of each loop, 4 LEDs
  • Output status indication, 16 LEDs
Maximum System Configuration
  • One access module plus up to 16 additional control or expansion modules (any combination), up to 152 loops
Mounting
  • DIN-rail specification EN50022, 1.38 x 0.30 in. (35 x 7.5 mm)
  • DIN-rail mounted or chassis mounted with customer supplied screws
Wiring Termination - Touch-Safe Terminals
  • Right angle and front screw type terminal blocks (slots A, B, D, E)
  • Input, power and controller output terminals, touch safe, removable, 12 to 30 AWG



Programmable Application Blocks

Compare
  • Greater than, less than, equal, not equal, greater than or equal, less than or equal
Counters
  • Counts up or down, loads predetermined value on the load signal. Output is active when the count value equals or exceeds predetermined target value
Linearization
  • Interpolated or stepped relationship
Logic
  • And, nand, or, nor, equal, not equal, latch, flip flop
Math
  • Average, process scale, deviation scale, differential (subtraction), ratio (divide), add, multiply, absolute difference, min., max., square root, sample and hold, altitude and dew point
Process Value
  • Sensor backup, average, crossover, wet/dry bulb, switch over, differential (subtraction), ratio (divide), add, multiply, absolute difference, min., max., square root, altitude, visala and dew point
Special Output Function
  • Compressor - turns on-off compressor for one or two loops (cool and dehumidify with single compressor)
  • Motorized valve - turns on-off motor open/closed outputs causing valve to represent desired power level
  • Sequencer - turns on-off up to four outputs to distribute a single power across all outputs with linear and progressive load wearing
Timers
  • On pulse - produces an output of fixed time on the active edge of timer run signal
  • Delay - output is a delayed start of timer run and off at same time
  • One shot - oven timer
  • Retentive - measures timer run signal and output on when accumulated time exceeds target
Variable
  • User value for digital or analog variable



Access Module Specifications (RMA)

(Select an RMA module for communication protocol options, datalogging and automatic configuration backup.)

Line Voltage/Power
  • Power consumption: 4 W, 9VA
  • Any external power supply used should comply with a Class 2 or SELV rating
Serial Communications
  • Isolated communications
  • All modules ship with standard bus protocol for configuration and communication connection to all EZ-ZONE products
Additional Communication Options
  • EIA 232/485, Modbus® RTU
  • EtherNet/IP™, Modbus® TCP, 10 BASE-T/100
  • BASE-TX
  • DeviceNet™
  • PROFIBUS DP (future option, contact factory)
  • USB, controller recognized as a device
Note: If an access module is present, all other modules must have Modbus® disabled in order to achieve communications with all of the modules.

USB
  • USB 1.1 device only
  • Mini USB connector type
  • Recognized as a mass storage device
Real Time Clock with Battery Backup
  • Accuracy (typical): ± 30ppm at 77ºF (25ºC)
  • +30/-100ppm overtemperature operating range
  • Battery type and typical lifetime rating: 10 years at 77ºF (25ºC)
  • Lithium battery used, recycle properly
Data Logging
  • 200 points
  • File storage on-board module
  • Common separated value (CSV) file type
  • Export files via removable SD micro memory card or USB communications port
Memory Card
  • Removable SD micro card
  • 2G SD memory card provided, also accepts other storage space amounts
  • -4 to 185ºF (-20 to 85ºC) ambient rating, non-volatile memory
  • Information access to configuration files and the ability to store module auto-configuration settings and datalog files if options have been ordered
Auto-configuration File Backup
  • Limited memory can support up to four modules
  • Limited memory is fixed on board
  • Unlimited memory can support up to 16 modules
  • Unlimited memory utilizes removable SD micro card option
Note: All module parameters are backed up in memory except for USER SET 1 and USER SET 2 parameter settings and address.


Compatible Accessories

Basic Remote User Interface (RUI) EZKB
The EZ-ZONE Remote User Interface (RUI and communications gateway) can be utilized as a communication gateway device to save cost, space and wiring when digital communications is being used with two or more EZ-ZONE controllers. The EZ-ZONE RUI can also serve as a display for showing all parameter values for up to 16 EZ-ZONE controllers, again saving cost, space and wiring expenses.



 MORE IMAGES 

· Connector Type Table

· Ring Terminal Connectors of EZ-ZONE® RM

· Front-Screw Connectors of EZ-ZONE® RM

· Standard Connectors of EZ-ZONE® RM

· EZ-ZONE® RM Family Comparison

· Implicit Messaging